Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
Talanta ; 207: 120277, 2020 Jan 15.
Artigo em Inglês | MEDLINE | ID: mdl-31594622

RESUMO

A low-cost and disposable microcell was constructed with a screen-printed electrode for the non-enzymatic electrochemical determination of creatinine. The working electrode was modified with carbon black and maintained in contact with paper-adsorbed iron (III) ions. A small sample volume of 3 µL was required for the device operation. Then, iron (III) ions were complexed in the presence of creatinine in a chemical step, followed by an electrochemical reduction of non-complexed metallic ions in excess. Cyclic voltammetry and differential-pulse voltammetry experiments were employed for the electrochemical characterizations and analytical performance evaluation of the microcell. The working electrode modification with carbon black provided a significant increase of analytical signal. The sensor presented a linear response for creatinine concentrations ranging from 0.10 to 6.5 mmol L-1, with a limit of detection of 0.043 mmol L-1. Experiments for creatinine determination in real samples were successful performed through of standard recovery in urine.


Assuntos
Creatinina/análise , Eletroquímica/instrumentação , Análise em Microsséries/instrumentação , Impressão , Creatinina/química , Creatinina/urina , Eletrodos , Química Verde , Humanos , Ferro/química , Limite de Detecção , Fuligem/química
2.
Talanta ; 203: 280-286, 2019 Oct 01.
Artigo em Inglês | MEDLINE | ID: mdl-31202339

RESUMO

A disposable microfluidic electrochemical paper-based device for multiplexed analysis based on sixteen independent microfluidic channels with electrochemical detection is proposed. A major advantage of this work was the non-necessary use of a wax printer for devices manufacturing which has a high cost of operation. In addition, a commercial multiplexing module was used that has the multiplexing capability of 8-16 channels and, for the first time using this module, the strategy of multiplexing both the working and reference electrodes were used. These sixteen channels with the respective sensors can be operated employing one or multiple electrochemical techniques with good repeatability and reproducibility for high throughput analysis. As a proof of concept, the electrochemical performance of device was tested with ferrocenecarboxylic acid solution employing cyclic voltammetry, square-wave voltammetry, differential-pulse voltammetry and chronoamperometry. This innovative sensing platform presented capacity of production in large scale and application for clinical tests with safety and short time of assays. A biosensor was constructed using glucose oxidase on the platform for the glucose determination in urine as a non-invasive strategy. The analytical curve was linear in the glucose concentration range from 1.0 × 10-4 mol L-1 to 4 × 10-2 mol L-1, with a limit of detection of 3 × 10-5 mol L-1.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...